Assumptions and calculation basis

- The typical Annual Energy Consumption (AEC) is calculated similar to the energy calculator of Energy Star: www.eu-energystar.org
- ESPRIMO P5905: 185W/ 73W/ 1W (PC in active use, PC in idle, PC off)
- ESPRIMO Mobile X9525: 59W/ 15W/ 1.8W (Notebook in active use/ in idle/ off)
- SCENICVIEW 17P4 CRT-monitor: 100W/ 8W/ 3W (on/ stand-by/ off)
- AMILO Display 19 inch" TFT Wide = AMILO L 3190T
- SCENICVIEW 19 inch" TFT Wide = SCENICVIEW E19W-10
- SCENICVIEW 19 inch" TFT = SCENICVIEW B19-5
- SCENICVIEW 22 inch" TFT Wide = SCENICVIEW P22W-5 ECO
- SCENICVIEW 24 inch" TFT Wide = SCENICVIEW B24W-5 ECO
- The Maximum Mode is measured according to SYSTEST 32 of Fujitsu Technology Solutions for workplace systems (to be replaced by Energy Star standard benchmarking tool when available).
- The “On-mode“ is determined by the proposal of the European MEEuP Product Cases Report (2005) based on the MEEuP Methodology Report for the European Commission (2005): “On-mode” for Home device is calculated by: 80% Idle, 20% full load / maximum, “On-mode” for Office device is calculated by: 90% Idle, 10% full load / maximum.
- Display power consumption of 0.0 watt in Off-Mode realized either with 0-Watt-Power-Save-Mode on selected SCENICVIEW display models or switched monitor outlet on power supply unit of certain PC models.
- Power management is set to normal. The choice of use for calculation is Home / Busy Office with the following usage patterns:

Power measurement at: 230 V / 50 Hz

Hours / day Consumer: Home (300 days/a) Business: Busy Office (260 days/a)
On-mode 2 8
Standby-Mode 9 2
Off-mode 13 14

Other day´s per year are calculated in Off-mode; WOL: Wake on LAN *)
ACPI: Advanced Configuration and Power Interface specification, an open industry standard, first released in December 1996
ACPI S0: Working, the normal working state of the computer
ACPI S3: known as Suspend to RAM (STR), Standby in versions of Windows through Windows
ACPI S5: Soft Off - some components remain powered so the computer can
"wake up" from input from the keyboard, clock, modem, LAN or USB device
- Energy value of brown coal: 10MJ/kg
- CO2-Emission by power production with an average of 575g/kWh (Issue: 03/2010 based on Umweltbundesamt Germany)


Disclaimer: This document is informal only. All energy consumption values are achieved by laboratory testing of the system configuration listed above. Your product may perform differently, depending on your user behaviour and on the software, components and peripherals you are using. Direct comparison of values from other systems is not possible because there are no existing standards for measurement procedures and tools for maximal/peak power consumption. The energy consumption for Clients and Displays is measured according to the measurement methods of the current Energy Star program, the international standard IEC 62301 and the established internal standard test program SYSTEST32 of Fujitsu Technology Solutions for the maximum value. This document may change without notice. Fujitsu Technology Solutions will update the information in line with technical progress.